Drive failures

Replace a failed drive and let RustFS heal the missing data onto the replacement.

RustFS uses erasure coding to keep data readable and writable when some drives fail. After you replace a failed drive, RustFS heals the missing data onto it automatically. For heal status and manual heal tasks, see Node healing.

Replace /data/rustfs0 and /dev/sdb with the mount and device for the failed drive. Confirm the device name before you format it. mkfs.xfs erases the selected device.

Stop RustFS and unmount the failed drive

Unmount the failed file system. If it has more than one mount point, unmount each one.

sudo umount /data/rustfs0

Device is busy

If umount reports that the device is busy, stop RustFS and any other process that still has the mount open, then run umount again.

sudo systemctl stop rustfs

Replace and prepare the drive

Install a replacement that is at least as large as the failed drive. Use XFS, the same file system as the other RustFS drives. Disk preparation explains how to identify the device and choose a unique label.

sudo mkfs.xfs -f -i size=512 -n ftype=1 -L RUSTFS0 /dev/sdb

Mount the replacement at the original path

The mount point must stay the path listed in RUSTFS_VOLUMES (in /etc/default/rustfs). Mount by file-system UUID so a reboot cannot attach the wrong drive if device names change.

/etc/fstab
UUID=<filesystem-uuid> /data/rustfs0 xfs defaults,noatime,nodiratime 0 0

Read the UUID after formatting:

sudo blkid -s UUID -o value /dev/sdb

Check /etc/fstab, then mount every entry and confirm the path:

sudo mount -a
findmnt /data/rustfs0

Start RustFS after the replacement is mounted:

sudo systemctl start rustfs

Confirm the file system has free space:

df -hT /data/rustfs0

Mount failed

If the mount fails, check that the UUID in /etc/fstab matches the new file system.

Watch healing

journalctl -u rustfs -f
tail -f /var/log/rustfs/rustfs.log

When RustFS sees a freshly formatted drive at a known mount point, it queues healing for the missing data. You can also check drive status on the Console, or follow the heal queue with rc as described in Node healing.

Healing reads healthy shards and writes reconstructed data, so disk and network utilization can rise while it runs. When the cycle finishes, the logs report success or list objects that failed to heal.

Follow-up checks

  • If several drives from the same manufacturing batch fail, inspect the remaining drives from that batch more often.
  • Rehearse this procedure so the team can follow it during an incident.